Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/16511
Tipo: Artigo de Periódico
Título: Evaluation of Sample Preparation Procedures for Trace Element Determination in Brazilian Propolis by Inductively Coupled Plasma Optical Emission Spectrometry and Their Discrimination According to Geographic Region
Título(s) alternativo(s): Food Analytical Methods
Autor(es): Korn, Maria das Graças Andrade
Guida, Mauro Agildo Barbosa
Barbosa, José Tiago Pereira
Torres, Ednildo Andrade
Fernandes, Andréa Pires
Santos, Josué Carinhanha Caldas
Dantas, Kelly das Graças Fernandes
Nóbrega, Joaquim de Araújo
Autor(es): Korn, Maria das Graças Andrade
Guida, Mauro Agildo Barbosa
Barbosa, José Tiago Pereira
Torres, Ednildo Andrade
Fernandes, Andréa Pires
Santos, Josué Carinhanha Caldas
Dantas, Kelly das Graças Fernandes
Nóbrega, Joaquim de Araújo
Abstract: Propolis is a complex mixture of substances collected by honeybees from buds or exudates of plants, beeswax, and other constituents, as pollen and sugars. The main purpose of this study was to evaluate two digestion procedures for determination of major, minor, and trace elements (Ba, Ca, Cd, Cr, Co, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, and Zn) in natura propolis samples by inductively coupled plasma optical emission spectrometry (ICP OES). The first procedure studied was an open-vessel digestion using HNO3 + H2SO4 + H2O2 in a heating block and the second one was a microwave-assisted concentrated acid digestion using HNO3 + H2O2. Both digestion procedures led to similar results and quantitative recoveries. The residual carbon contents (RCCs) for propolis sample digests were 0.269 ± 0.012 % when using the first procedure with conventional heating and 0.458 ± 0.023 % by microwave-assisted closed vessel digestion, demonstrating high efficiency of both procedures. Accuracy of the results was demonstrated using a certified reference material and by comparison with a recommended official method. The t test (unpaired) at 95 % confidence level showed that there was no significant difference between determined and certified values of all analytes under investigation, except Ca concentration employing conventional procedure. The optimized microwave-assisted digestion procedure led to recoveries around 89–103 % and precision better than 5 % for most samples. The second procedure was faster, safer, and more accurate than the one based on conductive heating. Additionally, principal component analysis (PCA) was applied for checking if there was correlation between inorganic composition and source of propolis samples collected around Bahia State in the Northeast of Brazil.
Palavras-chave: Propolis
Trace elements
Digestion
Microwave radiation
ICP-OES
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/16511
Data do documento: 2013
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Maria Graças Andrade Korn.pdf279,88 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.