Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14918
Tipo: Artigo de Periódico
Título: Direct determination of gallium in bauxite employing ICP OES using the reference element technique for interference elimination
Título(s) alternativo(s): Microchemical Journal
Autor(es): Santana, Fernanda Alves de
Barbosa, José Tiago Pereira
Matos, Geraldo D.
Korn, Maria das Graças Andrade
Ferreira, Sergio Luis Costa
Autor(es): Santana, Fernanda Alves de
Barbosa, José Tiago Pereira
Matos, Geraldo D.
Korn, Maria das Graças Andrade
Ferreira, Sergio Luis Costa
Abstract: The determination of gallium in bauxite samples using inductively coupled plasma optical emission spectrometry (ICP OES) is complicated because aluminum in high concentrations interferes strongly in this analysis. This paper proposes a direct method for the determination of gallium in bauxite samples by ICP OES employing the reference element technique for correction of aluminum interference. The experimental parameters: hydrochloric acid concentration used for preparation of gallium standard solutions and bauxite samples, nebulizer flow rate and RF power were optimized by multivariate technique. Firstly, a factorial design was performed for preliminary evaluation. Afterward, a Box–Behnken design was also performed for determination of the critical conditions for these factors. Box–Behnken design is a chemometric technique that in the last years has been often used for optimization of analytical methods. The procedure proposed using the established conditions (in presence of yttrium and/or scandium as reference element) allows the determination of gallium with limits of detection and quantification of 0.0006 and 0.0019 mg L− 1 and precision expressed as relative standard deviation of 4.37 and 1.78% for bauxite samples with gallium content of 21.00 and 36.00 mg Kg− 1. For sample mass of 0.20 g the limits of detection and quantification are 0.042 and 0.140 mg Kg− 1, respectively. The accuracy of the method was evaluated and confirmed using standard reference materials of alumina and marine sediment. The method proposed was applied for the determination of gallium in five bauxites, having yttrium and scandium as reference element, being that the sample preparation was done employing microwave-assisted digestion. The gallium content in the five samples varied from 19.70 to 100.59 mg Kg− 1. These concentrations are in agreement with the data reported by literature.
Palavras-chave: Gallium determination
Bauxite samples
ICP OES
Reference elements
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/14918
Data do documento: 2013
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S0026265X13000568-main.pdf215,47 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.