Title: Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN
Other Titles: Talanta
Authors: Ferreira, Sergio Luis Costa
Brito, Cristiane F. de
Dantas, Alailson Falcão
Araújo, Neyla Margarida Lopo de
Costa, Antonio Celso Spinola
Keywords: Nickel preconcentration;Inductively coupled plasma atomic emission spectroscopy;Inductively coupled plasma atomic emission spectroscopy;Alkaline salts
Issue Date: 1999
Publisher: Talanta
Abstract: In the present paper, a solid phase extraction system for separation and preconcentration of nickel (ng g−1) in saline matrices is proposed. It is based on the adsorption of nickel(II) ions onto an Amberlite XAD-2 resin loaded with 1-(2-pyridylazo)-2-naphthol (PAN) reagent. Parameters such as the pH effect on the nickel extraction, the effect of flow rate and sample volume on the extraction, the sorption capacity of the loaded resin, the nickel desorption from the resin and the analytical characteristics of the procedure were studied. The results demonstrate that nickel(II) ions, in the concentration range 0.10–275 μg l−1, and pH 6.0–11.5, contained in a sample volume of 25–250 ml, can be extracted by using 1 g Amberlite XAD-2 resin loaded with PAN reagent. The adsorbed nickel was eluted from the resin by using 5 ml 1 M hydrochloric acid solution. The extractor system has a sorption capacity of 1.87 μmol nickel per g of Amberlite XAD-2 resin loaded with PAN. The precision of the method, evaluated as the R.S.D. obtained after analyzing a series of seven replicates, was 3.9% for nickel in a concentration of 0.20 μg ml−1. The proposed procedure was used for nickel determination in alkaline salts of analytical grade and table salt, using an inductively coupled plasma atomic emission spectroscopy technique (ICP-AES). The standard addition technique was used and the recoveries obtained revealed that the proposed procedure shows good accuracy.
Description: Texto completo. Acesso restrito. p. 1173–1177
URI: http://www.repositorio.ufba.br/ri/handle/ri/12488
ISSN: 0039-9140
Appears in Collections:Artigos Publicados em Periódicos (Quimica)

Files in This Item:

File Description SizeFormat
444444444444444444444.pdf68.95 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

    Universidade Federal da Bahia

Contate-nos. Saiba mais sobre o RI/UFBA