Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/16149
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorTorres, Marianna Guanaes Gomes-
dc.contributor.authorCampos, Paulo Sérgio Flores-
dc.contributor.authorPena Neto Segundo, Nilson-
dc.contributor.authorNavarro, Marcus Vinícius Teixeira-
dc.contributor.authorRebello, Iêda Margarida Crusoé Rocha-
dc.creatorTorres, Marianna Guanaes Gomes-
dc.creatorCampos, Paulo Sérgio Flores-
dc.creatorPena Neto Segundo, Nilson-
dc.creatorNavarro, Marcus Vinícius Teixeira-
dc.creatorRebello, Iêda Margarida Crusoé Rocha-
dc.date.accessioned2014-09-23T14:54:57Z-
dc.date.issued2012-
dc.identifier.issn1056-6163-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/16149-
dc.descriptionTexto completo: acesso restrito. p. 150–155pt_BR
dc.description.abstractObjective: To evaluate the accuracy of linear measurements on dry mandible specimens using cone beam computed tomography (CBCT) images acquired with different voxel sizes. Methodology: Eight human dry mandibles were submitted to CBCT examination, using the i-CAT (Imaging Sciences, Inc. Hatfield, PA) device and four protocols with different voxel sizes. Tomographic slices with a more central view of the markers, placed on six sites on each mandible, were selected to perform measurements. Values obtained from direct measurements on the dry mandible after sectioning them on the preestablished sites were compared with measurements from the tomographic images and the measurement error. Results: There was no statistical difference between the measurement error of the protocols (P = 0.606). The mean value of the difference between the values obtained in the images and the dry mandible was smaller than 1 mm for all the protocols. Conclusion: The accuracy of vertical and horizontal measurements, using CBCT (i-CAT) for the four protocols, was shown to bpt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/ 10.1097/ID.0b013e31824bf93cpt_BR
dc.subjectcone beam computed tomographypt_BR
dc.subjectTomographypt_BR
dc.subjectVoxelpt_BR
dc.titleAccuracy of Linear Measurements in Cone Beam Computed Tomography With Different Voxel Sizespt_BR
dc.title.alternativeImplant Dentistrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 21, n. 2pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Marianna Guanaes Gomes Torres.pdf637,94 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.